By August 6, 2015 0 Comments Read More →

SWITCHGEAR (OPERATION, MAINTENANCE & TESTING)

SWITCHGEAR (OPERATION, MAINTENANCE & TESTING)

Yogyakarta | 11 – 13 Agustus 2015 | Rp 6.000.000,-/participant
Yogyakarta | 15 – 17 September 2015 | Rp 6.000.000,-/participant
Yogyakarta | 20 – 22 Oktober 2015 | Rp 6.000.000,-/participant
Yogyakarta | 10 – 12 November 2015 | Rp 6.000.000,-/participant
Yogyakarta | 01 – 03 Desember 2015 | Rp 6.000.000,-/participant

 

 

DESKRIPSI TRAINING SWITCHGEAR

Switchgears (& circuit breakers) merupakan komponen penting dalam sistem distribusi listrik dan pengoperasiannya secara signifikan mempengaruhi operasi keseluruhan sistem. Pengoperasian medium voltage switchgear, dan testing adalah masalah yang berkaitan dengan listrik, dan voltage circuit breakers type high, medium, dan juga akan ada cakupan switchgear tegangan rendah (low voltage switchgear).

Pelatihan ini akan memberikan landasan menyeluruh dalam teori switchgear dan standard-nya. Peserta akan mendapatkan pemahaman mengenai aplikasi yang tepat, instalasi dan maintenance terhadap peralatan penting ini dengan penekanan utama pada aspek safety. Pelatihan akan bersifat komprehensif dan praktis, yang menekankan switchgear tegangan menengah (medium voltage switchgear) yang mewakili sebagian besar switchgear diinstal pada sistem distribusi listrik. Komponen sistem proteksi daya lainnya akan dibahas juga untuk memastikan bahwa switchgear dipahami dalam konteks yang benar.



TUJUAN TRAINING SWITCHGEAR

Setelah mengikuti pelatihan ini, diharapkan peserta akan memahami tentang hal-hal berikut:

  • Dapat melakukan pemilihan jenisyang tepatdanrating dari circuit breakers danswitchgear
  • Memahami dasar-dasar pengoperasian switchgear
  • Mengetahui tentang komponen Switchgear (CTs, VTs, relay, terminasi kabel)
  • Mengetahui kebijakan safety operasional, termasuk peraturan keselamatan dan keamanan dokumen
  • Memahami pengoperasian switchgear
  • Mampu melakukan pemeliharaan/maintenance dan testing pada switchgear.



MATERI TRAINING SWITCHGEAR

  1. SWITCHGEAR – ORIGINS & TYPES
  2. APPLICATION OF SWITCHGEAR
  • Principles of current interruption
  • Plain break circuit breakers
  • Bulk and small oil volume circuit breakers
  • Turbulator (explosion pot)
  • Operating mechanisms
  • Transfer earth circuit breakers
  • Air break and air blast switchgear
  • SF6 and Vacuum
  • Switchgear in association with disconnectors
  • Fixed and withdrawable designs
  • Switchgear standards
  • Factors affecting switchgear selection
  1. SPECIFICATION OF SWITCHGEAR
  • Switchgear rating – highest system and impulse withstand voltages, load and short circuit currents
  • Simple and complex protection systems
  • Switchgear ancillaries, measurement CTs, VTs, relays
  • Cable terminations
  • Indoor and outdoor operation
  • Substation and switch room layouts and design
  1. SHORT CIRCUIT TESTING
  • Symmetrical and asymmetrical breaking
  • Make and break operations
  • Understanding test oscillograms
  1. SAFETY POLICIES
  • General safety precautions and the use of personal protective equipment
  • Principles of safety rules
  • Principles of personnel authorisation
  • Operative training for safe operation of switchgear
  • Isolation in a circuit breaker context
  • Safety documentation
  • Operational and safety locking, caution and danger notices
  • Safe working in a substation environment
  • Safety interlocks
  • Substation alarms
  • Individual study task and presentation -safety policies in my company and how they might be improved
  1. OPERATION OF MODERN SWITCHGEAR
  2. ASSET MANAGEMENT IN A SWITCHGEAR CONTEXT
  • Principles of time and condition based asset management
  • Asset registers
  • Asset management systems
  1. DIAGNOSTICS, TESTING & MAINTENANCE
  • Switchgear inspection methodologies
  • Partial discharge measurement and survey
  • Timing tests
  • Thermovision
  • Mechanisms of deterioration
  • Principles of circuit breaker maintenance
  • Maintaining oil circuit breakers
  • Contact maintenance and contact wipe
  • Oil testing
  • Maintaining vacuum circuit breakers
  • Maintaining SF6 circuit breakers
  • SOPs and DINs
  • Switchgear defects and defect control systems



PESERTA

Pelatihan ini sesuai untuk diikuti oleh para personel yang bertanggung jawab dalam proses maintenance, testing dan troubleshooting low voltage power circuit breakers, protective relays, breaker trip devices dan switchgear panels.



METODE

  • Presentasi
  • Diskusi Interaktif
  • Simulasi
  • Studi Kasus
  • Evaluasi



INSTRUKTUR

  • Janny F. Abidin, S.T., M.T.
  • Tugino, S.T., M.T.

(Praktisi Electrical Engineering)

 

 

WAKTU & TEMPAT TRAINING SWITCHGEAR

  • Batch 8 : 11 – 13 Agustus 2015
  • Batch 9 : 15 – 17 September 2015
  • Batch 10 : 20 – 22 Oktober 2015
  • Batch 11 : 10 – 12 November 2015
  • Batch 12 : 1 – 3 Desember 2015
  • 08.00 – 16.00 WIB
  • Ibis Malioboro Hotel Yogyakarta ; Ibis Styles Hotel Yogyakarta ; Horison Hotel Yogyakarta

In House Training : Depend on request



BIAYA

Rp 6.000.000,- /participant (non residensial)*

Special Rate:

Rp 5.500.000,- (min 3 participants from the same company)



FASILITAS

  • Meeting Room di Hotel
  • Module/Materi (hard & soft copy)
  • Training Kit
  • Coffe Break & Lunch
  • Souvenir
  • Sertifikat
  • Airport pick up services
  • Transportation during training

Formulir Permintaaan Informasi Lanjutan / Pra-Pendaftaran Public Training
  1. INFORMATION OPTIONS
  2. (required)
  3. (required)
  4. PERSONAL DATA
  5. (required)
  6. (required)
  7. (required)
  8. (valid email required)
  9. (required)
  10. (required)
  11. PRE REGISTRATION DATA (Tidak Mengikat)
  12. (required)
  13. MESSAGE FOR TRAINING PROVIDER
 

cforms contact form by delicious:days

About the Author:

Post a Comment