By March 19, 2012 0 Comments Read More →

ELECTRICAL INSULATION

ELECTRICAL INSULATION : SELECTION, TESTING, AND MAINTENANCE

Hotel All Seasons – Yogyakarta | 20 – 22 Maret 2012 | IDR  5.000.000 per participant
Hotel All Seasons – Yogyakarta | 8-10 April  2012 | IDR  5.000.000 per participant
Hotel All Seasons – Yogyakarta | 06 – 08  Mei  2012 | IDR  5.000.000 per participant
Hotel All Seasons – Yogyakarta | 26 – 28 Juni 2012 | IDR  5.000.000 per participant
Hotel All Seasons – Yogyakarta | 03 – 05 Juli 2012 | IDR  5.000.000 per participant
Hotel All Seasons – Yogyakarta | 04 – 05  September 2012 | IDR  5.000.000 per participant
Hotel All Seasons – Yogyakarta | 16-18 Oktober  2012 | IDR  5.000.000 per participant
Hotel All Seasons – Yogyakarta | 06-08 November 2012 | IDR  5.000.000 per participant
Hotel All Seasons – Yogyakarta | 11-13 Desember 2012 | IDR  5.000.000 per participant




OBJECTIVES

  1. Understand the materials characteristic of dielectric, behavior of electric field, and isolation material classification
  2. Understand various insulation material
  3. Understand the application of insulation in electrical system
  4. Understand the method to measure and testing of insulation
  5. Understand how to maintain of electrical insulation


COURSE OUTLINE

  1. Define insulation electrical problem
  2. Role and function of insulation in electric power system
  3. International standard and code of electrical insulation:
    • o Hazardous area classification
  4. o Non-hazardous area classification
  5. Characteristic of dielectric materials
  6. Interaction between dielectric material with electric field based on type of insulation material; gas, liquid, and solid
  7. Stress, penetration stress and penetration probability, stress-time curve, and insulation coordination
  8. The Use of insulator and level of insulation for:
    • o Electrical equipment
    • o Cables
    • o Transformer
    • o Electric motor
    • o Generator
    • o Circuit breaker, etc
  9. Characteristic of various insulators :
    • o SF6
    • o Vacuum
    • o Gas,
    • o Composite, etc
  10.  Measurement and diagnostic of dielectric, and insulator testing
  11. Maintenance of electrical equipment isolation
  12. Case study



INSTRUCTOR

Ir. Teguh Puji, MT and team



WHO SHOULD ATTEND?

  1. Mechanical & Electric Engineer/ Supervisor /Superintendent
  2. Electrical Design Engineer, Electric Plant Maintenance Engineer/ Supervisor/ Superintendent
  3. Engineer from electrical equipment manufacture
  4. Safety and Loss Control Engineer/ Supervisor/ Superintendent
  5. Everybody or professional who wants to broaden knowledge or gain Benefit from this course



DELIVERY TYPE

Lecturing, interactive discussion, and case study.


TIME & VENUE

  • 20-22 Maret / 8-10 April / 6-8 Mei / 26-28 Juni / 3-5 Juli / 4-5 September / 16-18 Oktober / 6-8 November / 11-13 Desember 2012
  • Hotel All Seasons – Yogyakarta



INVESTATION

IDR 5.000.000 per participant – non residential



FACILITIES

  • Quality Training module
  • Stationeries: notebook and ballpoint
  • Training bag or backpack
  • Morning and afternoon coffee break for a long of the training
  • Exclusive T-Shirt
  • Certificate of Completion
  • Training photo
  • Transportation for participants from the airport/railway station to hotel/training venue (Minimal number of participants from the same company is 2 persons)

 

Formulir Permintaaan Informasi Lanjutan / Pra-Pendaftaran Public Training
  1. INFORMATION OPTIONS
  2. (required)
  3. (required)
  4. PERSONAL DATA
  5. (required)
  6. (required)
  7. (required)
  8. (valid email required)
  9. (required)
  10. (required)
  11. PRE REGISTRATION DATA (Tidak Mengikat)
  12. (required)
  13. MESSAGE FOR TRAINING PROVIDER
 

cforms contact form by delicious:days

Posted in: Electrical, Yogyakarta

About the Author:

Post a Comment