INDUSTRIAL VARIABLE SPEED DRIVE (VSD)
INDUSTRIAL VARIABLE SPEED DRIVE (VSD)
Bali | 24 – 26 Juni 2014 | Rp. 8.000.000
Bandung | 24 – 26 Juni 2014 | Rp. 6.500.000
Yogyakarta | 24 – 26 Juni 2014 | IDR 6.000.000
Bali | 02 – 04 Juli 2014 | Rp. 8.000.000
Bandung | 02 – 04 Juli 2014 | Rp. 6.500.000
Yogyakarta | 02 – 04 Juli 2014 | 6.000.000
Bali | 15 – 17 Juli 2014 | Rp. 8.000.000
Bandung | 15 – 17 Juli 2014 | Rp. 6.500.000
Yogyakarta | 15 – 17 Juli 2014 | 6.000.000
Jadwal Training 2014 Selanjutnya …
DESCRIPTION
Pumps, fans, blowers and compressors consume as much as 65% of this total. A large proportion of these applications are powered by fixed or constant speed drivers whose load demands often fluctuate. This poor match of speed and demand results in considerable wasted energy and significantly increased wear of system components. Variable speed drive technology is a cost effective method to match driver speed to load demands and is an excellent opportunity to reduce operating costs and improve overall efficiencies in your application.
This course gives you a fundamental understanding of the installation, operation and troubleshooting of variable speed drive. You will learn the basic setup of parameters, control wiring and safety precautions in installing a VSD. The various drive features such as operating modes, braking types, automatic restart and many others will be discussed in detail. You will learn the four basic requirements for a VSD to function properly with emphasis on typical controller faults, their causes and how they can be repaired.
The concluding section of the course gives you the fundamental tools in troubleshooting VSD confidently and effectively. Even though the focus of the course is on the direct application of this technology, you will also gain a thorough understanding of the problems that can be introduced by VSD such as harmonics, electrostatic discharge and EMC/EMI problems.
OBJECTIVES
At the end of this course participants will be able to:
- Demonstrate a sound understanding of how AC Variable Speed Drive (VSD’s) work
- Install VSDs properly
- Select the right VSD for a given application
- Troubleshoot VSDs competently
- Competently explain how flux-vector control works for drive applications understand squirrel cage induction motors
- Identify the protection and control system requirements for VSD’s
- Interface VSD’s with PLCs
- Understand the causes of motor burnout
- Deal effectively with VSD harmonics and
- EMC/EMI problems
COURSE OUTLINE INDUSTRIAL VARIABLE SPEED DRIVE (VSD)
Introduction To Variable Speed Drive
- The Need for Variable Speed Drive
- Fundamental Principles of Speed Control
- Efficiency, Torque, Inertia,
- Horsepower/Power Factor
- Torque-Speed Curves
- How the motor produces Torque
- Types of Variable Speed Drive
3-Phase AC Induction Motors
- Basic Construction and Physical Configuration
- Principles of Operation and Performance
- Equivalent Circuit and Fundamental Equations
- Starting, Acceleration, Running and Stopping
- Power, Torque and Thermal Rating
Power Electronic Converters
- Definitions and Basic Principles
- Power Diodes and Thyristors
- Principles of Communication
- Power Electronic Rectifiers
- Power Electronic Inverters
- Gate Commutated Converters
- Gate Controlled Devices – GTO, FCT, GTR, FET, IGBT
Electromagnetic Compatibility (EMC)
- Sources of Electromagnetic Interference
- Harmonics on the Power Supply side of AC Converters
- The Effect of Harmonic Distortion on other connected Equipment
- Methods of reducing the effect of Supply side Harmonics
- Electric Motor Protection
- Thermal Overload Protection – Current Sensing
- Thermal Overload Protection – Direct Temperature Sensing
Protection Of Motors And Converters
- AC Frequency Converter Protection Fault Diagnostics
- Electric Motor Protection
- Thermal Overload Protection – Current Sensors
- Thermal Overload Protection – Direct Temperature
Control System For AC Variable Speed Drive
- The Overall Control System
- Power Supply to the Control System
- DC Bus Charging System
- VSD Control Loops (Open-Loop, Closed- Loop)
- Vector control and its applications Current Feedback in AC Variable Speed Drive
- Speed Feedback from the Motor
The Selection Of AC Converters For Variable Speed Drive Applications
- The Basic Selection Procedure
- Loadability of Converter Fed induction Motors
- Operation in the Constant Power Region\
- The Nature of the Machine Load
- Starting and Stopping VSDs (Motor Braking)
The Selection Of AC Converters (Continued)
- How to Calculate Acceleration Torques and Times
- How to Select the correct Motor and
- Converter for Pump and Fan Loads
- How to Select the correct Motor and
- Converter for Constant Torque Loads, such as conveyors
- Summary of the Selection Procedure
Installation And Fault Finding Techniques
- General Installation and Environmental Requirements
- Power Supply Connections and Earthing
- Where to install the Contactors in the Power Where to install the Contactors in the Power Circuit
- Installing AC Converters into Metal Enclosures
METODE
Lecturing, workshop, interactive consultation, study visit, and practice
INSTRUKTUR
Miftahul Huda, ST M.Eng and team
TIME & VENUE
- 24-26 Juni / 2-4 Juli / 15-17 Juli/ 22-24 Juli / 4-6 Agustus / 12-14 Agustus / 19-21 Agustus / 1-3 September / 22-24 September / 24-26 September / 1-3 Oktober / 15-17 Oktober / 29-31 Oktober / 3-5 November / 12-14 November /25-27 November / 2-4 Desember / 15-17 Desember / 29-31 Desember 2014
- Hotel Ibis Styles Dagen – Yogyakarta
TRAINING FEE
- IDR 6.500.000 per participant (Non-Residential)
- Minimal participants : 2 persons (Yogyakarta
- Bali, Ibis Styles Kuta, Ibis Legian Hotel, Hard Rock Café Hotel | Rp. 8.500.000 Per Peserta | Kuota Min. Peserta: 5 orang
- Bandung, De Batara Hotel, Banana Inn Hotel, Golden Flower hotel | Rp. 7.500.000 Per Peserta | Kuota Min. Peserta: 5 orang
FASILITAS
- Training module industrial variable speed drive (hard copy)
- Training kit (tas seminar atau backpack)
- 2x coffee break, 1x lunch
- Souvenir
- Sertifikat
- Training Photo
- Picking-up service dari Bandara/Stasiun KA ke hotel (min. 2 orang peserta dari perusahaan yang sama