By December 20, 2019 0 Comments Read More →

Electrical Maintenance Low & Medium Voltage – PASTI JALAN

Kelas Electrical Maintenance ini membahas sistem tenaga tegangan menengah termasuk komponen, desain & masalah operasi

Yogyakarta/ Semarang/ Solo | 06 – 07 Januari 2020 | Rp. 6.900.000
Bandung/ Jakarta/ Surabaya | 13 – 14 Januari 2020 | Rp. 7.900.000
Bali/ Batam/ Balikpapan/ Manado/ Lombok | 20 – 21 Januari 2020 | Rp. 8.900.000
Bandung/ Jakarta/ Surabaya | 03 – 04 Februari 2020 | Rp. 7.900.000 – PASTI JALAN

Jadwal Training 2020 Selanjutnya…

 

 

Medium Voltage and Low  Training Description

The backbone of many electric power systems is the medium voltage distribution system. Typically operating at voltages ranging from 2,400 to 34,500 Volts, voltage stress, corona, surges and protection of equipment all create unique challenges in design, equipment selection, operation and engineering. This 2 day class takes you through the basics of medium voltage power systems including components,equipment, design and operation problems as well as protection of medium voltage systems.

 

Medium Voltage and Low Training Outline

  1. MEDIUM VOLTAGE SAFETY
    • Electrocution at Low vs. Medium Voltage, Arc Flash,
    • Qualified Person, Approach Boundaries
  2. TYPES OF MEDIUM VOLTAGE SYSTEMS
    • Utility and Industrial One lines, Reliability Requirements,
    • Overhead and Underground Systems, Regulated Systems
  3. MEDIUM VOLTAGE CABLE
    • Copper vs. Aluminum Design, Voltage Ratings
    • Insulation Ratings, 100%, 133%, 173% Insulation Levels,
    • Shielding Requirements, Electric Fields, Terminating MV
    • Conductors, Orientation of Overhead Lines
  4. MEDIUM VOLTAGE SUBSTATION TRANSFORMERS
    • Core and Coil Design, Aluminum and Copper Windings
    • Tank Construction, Loss Evaluation, Efficiency, Regulation
  5. SPOT NETWORKS
    • Spot Network Design, Network Protectors, Network Protector
    • Relay Operation, Directional Protection Requirements
  6. PARTIAL DISCHARGE
    • Corona, Surface Tracking, Voltage Stress, Sensing Partial
    • Discharge, Component Failure
  7. GROUNDING MEDIUM VOLTAGE SYSTEMS
    • Resistance Grounding, Solid Grounding, Ungrounded Delta
    • Charging Current, Effect of Ground Faults on Delta Voltage
  8. SURGE PROTECTION
    • Lightning and Switching Surges, Classes of Surge Arresters
    • MCOV Ratings – (Maximum Continuous Operating Voltage)
    • TOV – (Maximum Temporary Over Voltage Capability),
    • Protective Characteristics, Surge Arrester Selection, Energy
    • Capability, Effect of Grounding on Arrestor Selection,
    • Insulation Coordination,
  9. CURRENT TRANSFORMER APPLICATIONS
    • Ratings, Selection Process, Accuracy, Saturation, Excitation
    • Curves, Burden Calculation, Momentary Ratings
  10. MEDIUM VOLTAGE CIRCUIT BREAKERS
    • Vacuum, Air, Oil, SF6 Designs, Symmetrical Interrupting
    • Rating, K-Rated Voltage Factor, Close and Latch Capability
  11. RECLOSERS
    • Application on Feeder Circuits, Recloser Settings
    • Continuous Current and Interrupting Ratings
  12. MEDIUM VOLTAGE FUSES
    • Medium Voltage Switches, Load Rating, Close and Latch
    • Rating, Short Time Rating, Expulsion vs. Current Limiting
    • Fuse Characteristics, E and R Rated Fuses, Fuse Cutouts
  13. MEDIUM VOLTAGE PROTECTION CONCEPTS
    • Medium Voltage Protection, Relays, Circuit Breakers, R and
    • Erated Fuses, Short Circuit vs. Overcurrent Protection
  14. DISTRIBUTION FEEDER PROTECTION
    • Protection with Fuses – 300%, Overcurrent Protection with
    • Relays – 600%, Short Circuit Damage Characteristics, Relay
    • “Reach” for End of Line Faults
  15. ROTATING MACHINERY PROTECTION
    • Requirements, Decrement Curves, Thermal Damage Curves,
    • Reactive, Capability Curves, Differential Protection
  16.  MEDIUM VOLTAGE MOTOR CONTROLLERS
    • Protection Requirements, Motor Management Relays, Circuit
    • Breaker Protection, Relaying, Class R Rated Fuses
  17. TRANSFORMER PROTECTION
    • ANSI C57 Thru Fault Curves, Impact of Transformer Winding
    • Configuration, Overview of Differential Protection, Inrush and
    • Harmonic Restraint

 

Participants

  • D3 atau SLTA yang berpengalaman kerja minimal 3 tahun, dan atau setara.
  • Teknisi, Operator dan Supervisor didalam bidang management kelistrikan dan atau non teknik.
  • Mereka yang dalam tugasnya berhubungan dan atau terkait dengan materi kursus.

 

Metode

Presentation, discuss, case study.

 

Waktu  Dan Tempat Training 2020

  • Hotel Santika Kuta, Bali
  • Hotel Nagoya Plaza, Batam
  • Hotel Fave, Balikpapan
  • Hotel Aston, Manado
  • Hotel Lombok Raya, Mataram
  • Hotel Serela Merdeka, Bandung
  • Hotel Santika Pandegiling, Surabaya
  • Sofyan Hotel Betawi, Jakarta
  • Hotel Ibis Solo
  • Hotel Ibis Simpang Lima, Semarang
  • Hotel Ibis Malioboro, Yogyakarta
  • 6 – 7 Januari 2020
  • 13 – 14 Januari 2020
  • 20 – 21 Januari 2020
  • 27 – 28 Januari 2020
  • 3 – 4 Februari 2020
  • 10 – 11 Februari 2020
  • 17 – 18 Februari 2020
  • 26 – 27 Februari 2020
  • 2 – 3 Maret 2020
  • 9 – 10 Maret 2020
  • 16 – 17 Maret 2020
  • 23 – 24 Maret 2020
  • 30 – 31 Maret 2020
  • 6 – 7 April 2020
  • 13 – 14 April 2020
  • 20 – 21 April 2020
  • 27 – 28 April 2020
  • 4 – 5 Mei 2020
  • 11 – 12 Mei 2020
  • 2 – 3 Juni 2020
  • 8 – 9 Juni 2020
  • 15 – 16 Juni 2020
  • 22 – 23 Juni 2020
  • 29 – 30 Juni 2020
  • 6 – 7 Juli 2020
  • 13 – 14 Juli 2020
  • 20 – 21 Juli 2020
  • 27 – 28 Juli 2020
  • 3 – 4 Agustus 2020
  • 10 – 11 Agustus 2020
  • 18 – 19 Agustus 2020
  • 24 – 25 Agustus 2020
  • 31 Agustus 2020 – 1 September 2020
  • 7 – 8 Sepember 2020
  • 14 – 15 September 2020
  • 21 – 22 September 2020
  • 28 – 29 September 2020
  • 5 – 6 Oktober 2020
  • 12 – 13 Oktober 2020
  • 19 – 20 Oktober 2020
  • 26 – 27 Oktober 2020
  • 2 – 3 November 2020
  • 9 – 10 November 2020
  • 16 – 17 November 2020
  • 23 – 24 November 2020
  • 30 November 2020 – 1 Desember 2020
  • 7 – 8 Desember 2020
  • 14 – 15 Desember 2020
  • 21 – 22 Desember 2020
  • 28 – 29 Desember 2020

 

Investasi dan Fasilitas

  • Rp 8.900.000 (Non Residential) untuk lokasi di Bali, Batam, Balikpapan, Manado atau Lombok
  • Rp 7.900.000 (Non Residential) untuk lokasi di Bandung, Jakarta atau Surabaya
  • Rp 6.900.000 (Non Residential) untuk Lokasi Solo, Semarang atau Yogyakarta
  • Quota minimum 2 peserta
  • Quota minimum 3 peserta ( Untuk Manado, Balikpapan dan Lombok Quota minimal 4 peserta)
  • Fasilitas : Certificate,Training kits, USB,Lunch,Coffe Break, Souvenir
  • Untuk peserta luar kota disediakan transportasi antar-jemput dari Bandara/Stasiun ke Hotel khusus bagi perusahaan yang mengirimkan minimal 3 orang peserta)

 

Instrktur Training

Tugino, ST.,MT dan Tim

Having knowledge and experience as practician and trainer in Electricity Maintenance.

 

Electrical Maintenance Low and Medium Voltage: Trouble Shooting

Formulir Permintaaan Informasi Lanjutan / Pra-Pendaftaran Public Training
  1. INFORMATION OPTIONS
  2. (required)
  3. (required)
  4. PERSONAL DATA
  5. (required)
  6. (required)
  7. (required)
  8. (valid email required)
  9. (required)
  10. (required)
  11. PRE REGISTRATION DATA (Tidak Mengikat)
  12. (required)
  13. MESSAGE FOR TRAINING PROVIDER
 

cforms contact form by delicious:days

About the Author:

Post a Comment